Energy Savings from infra red
The following energy-comparison studies were undertaken on different-sized family houses using different types of heating. The results clearly indicate Infrared Heating required up to 70% less energy to heat the respective houses to the same acceptable standard as under their former sources of heat. Act on CO2 today by switching to Infrared.
Redwell Infrared Heater systems
"click to enlarge"
====================================================
"click to enlarge"
====================================================
"click to enlarge"
Energy-efficiency demonstrated by Redwell Infrared Heaters
Further experiments were performed to determine the heat-efficiency over time, by using infra red heat to maintain a constant level of comfort in the indoor temperature despite changes in outdoor temperature. The point being that with standard convection-based heating, large changes in outside temperature typically requires a large change in energy required to heat the house (house insulation remaining the same before and during the experiment). The tests demonstrate that whilst heating was required as the outside air temperature dropped (i.e. house insulation was not perfect), the heat energy required to maintain comfort was far lower than standard convection-based heating. Consequently heating bills over the winter period may be considered a fraction of what they would be using convection heating.
Single Family House - Swiss Midlands - ROOM 1
Energy Saving Construction
| Roomdata | Room 1 - Playroom |
| outer walls | u/value 0,23 W/m2K |
| windows | u/value 1,55 W/m2K |
| heated net area | 12,70 m2 |
| heated net volume | 30,50 m3 |
| heat output needed | 451 W |
Statistics period from 1.10.2007 - 31.3.2008
| Max. outside temp. | 23,2 C | Max. wind speed | 65,25 Mph |
| Min. outside temp. | - 8,10 C | Min. wind speed | 0,00 Mph |
| Average outside temp. | 4,10 C | Average wind speed | 5,78 Mph |
"click to enlarge"
| Energy costs: 208 kWh x 0,10 £ = 20,80 £ (here) |
| (room - total heating period) |
===================================================
Single Family House - Swiss Midlands - ROOM 2
Energy Saving Construction
| Roomdata | Room 2 - Playroom |
| outer walls | u/value 0,23 W/m2K |
| windows | u/value 1,55 W/m2K |
| heated net area | 17,00 m2 |
| heated net volume | 40,80 m3 |
| heat output needed | 612 W |
Statistics period from 1.10.2007 - 31.3.2008
| Max. outside temp. | 23,2 C | Max. wind speed | 65,25 Mph |
| Min. outside temp. | - 8,10 C | Min. wind speed | 0,00 Mph |
| Average outside temp. | 4,10 C | Average wind speed | 5,78 Mph |
"click to enlarge"
| Energy costs: 325 kWh x 0,10 £ = 32,50 £ (here) |
| (room - total heating period) |